Taiguo LSS Vertical Gas Steam Boiler
Release time: 2017-04-26 Clicks:

[LSS type vertical fuel gas steam boiler-product pictures are as follows]

LSS gas steam boiler
LSS gas steam boiler
I. Structure Introduction:
燃气锅炉 为立式快装内燃弯水管锅炉。 LSS type gas boiler is a vertical fast-installed internal combustion bent water tube boiler. The fuel enters the burner from the external gas source and generates high-temperature flames through the functions of automatic adjustment and automatic ignition. Then, it is folded 180 ° from the lower flue port of the furnace to the rib layer between the cylinder and the packaging layer. After the heat is transferred between the ribs, the flue gas leaves the boiler through the upper flue port and is discharged into the atmosphere. The boiler is equipped with a technically good burner, which adopts advanced technologies such as automatic combustion proportional adjustment, automatic feed water adjustment, program start and stop, and fully automatic operation. . This type of boiler has the characteristics of compact structure, safety and reliability, easy operation, rapid installation, less pollution, low noise, high efficiency and so on.
Second, the product factory profile:
The boiler leaves the factory for complete assembly. Burners, automatic consoles, water pumps, valves, meters, flue ducts, etc., are shipped from the factory according to the drawings or according to the contract. Provide two random technical documents according to the factory technical document list.
3. Control system description:
The gas boiler uses a fully automatic burner with good technical performance as the main combustion equipment. The burner's combustion program is controlled by a more advanced combustion program controller, which can achieve various functions necessary for the normal combustion of the boiler, and can be in a normal state. In case of accidents and unusual circumstances, protective furnace shutdown is automatically implemented, with corresponding water level controllers and pressure regulators to achieve high and low water level indication, overpressure indication and adjustment, to ensure that the water level fluctuates within the normal range, and the steam pressure is allowed Within the range of pressure fluctuation, when the water level is extremely low, a protective stop instruction is realized when the pressure is too high.
1. Basic operations:
Turn on the power and press the "Start" key, the controller will turn on, the buzzer will sound, and the digital display window will display the steam pressure.
Press the "Start" key, the running indicator lights up, and the controller works according to the selected control requirements
Press the "Stop" key, the running indicator goes out, and the controller stops running.
2. Setting operation:
Press the "Set" key, the setting indicator lights up, indicating that the setting state is entered, at the same time the setting value indicator lights, press the "+", "-" keys to modify.
⑴Current time:
The current time, using a 24-hour clock, this setting takes effect immediately when modified.
Start-up time: When the current time reaches the start-up time, the boiler enters the operating state.
Stop time When the current time reaches the stop time, the boiler stops running.
3. The main control parameters:
⑴. Pressure control:
① The pressure regulator is adjusted to 0.71 MPa.
② The pressure regulator is adjusted to 0.72MPa.
⑵. Water level control:
①Water level controller SZB-IV (electrode type water level alarm)
a. When the normal water level is + 30mm, the pump control switch contact is disconnected and the pump stops working.
b. When the normal water level is -30mm, the pump control switch contacts come into contact and the pump starts to work.
c. When the normal water level is + 50mm, the first group of electromagnet high water level contacts will output an extremely high water level alarm signal.
d. When the normal water level is -50mm, the low water level contact of the second group of electromagnets will output an extremely low water level alarm signal.
⑶. Ignition control:
The combustion program controller provides a set of independent start-stop control contacts. Various burners can be prepared. The start-stop control relay circuit is connected with a 10A fuse. The start-stop control relay can be connected to the start-stop control terminal of the burner, and it can also directly control the power of the burner.
⑷Exhaust gas temperature control
① The thermocouple measurement range is adjusted to 160 ~ 250 ℃.
4. Alarm signal status:
① When the normal water level is + 50mm, a yellow indicator light is on, indicating the high water level status.
② When the normal water level is -50mm, a red indicator light is on, and an electric bell rings to indicate a low water level alarm, and the pump startup procedure is started.
③ When the normal pressure is 0.7MPa or more, a red indicator light is on, indicating that the pressure exceeds 0.71MPa and the first-level (small fire) fire state is implemented.
④ When the pressure exceeds 0.72MPa, the electric bell sounds, the power of the burner is cut off, and an emergency shutdown is implemented.
⑤ When the burner cannot work normally due to various faults, the output failure alarm, the red indicator light is on, and the electric bell rings.
⑥ When the exhaust temperature is higher than 250 ℃, a blue indicator light is on, accompanied by an electric bell, indicating that the exhaust temperature exceeds the allowable value. Measures should be taken immediately to reduce the exhaust temperature to the allowable value.
5. Indication status:
① When the pump is running and in the automatic state, the "auto" signal light is on, and in the manual state, the "manual" signal light is on, which is indicated by a green indicator light.
② High water level, big fire burning, low fire burning and other states are indicated by yellow indicator lights.
③ Low water level, very low water level, overpressure, burner failure and other states are indicated by red indicator lights.
④ Over temperature is indicated by blue indicator light.
6. System control principle:
①. After closing the power switch, click on the pump control switch to open the position, after the boiler feed water is raised to the normal position, click on the burner power switch, click the start button, the control system power is turned on, the burner enters the working state, and control according to the program The operation procedure of the device is to start the low-fire combustion and then enter the high-fire combustion state. At this point, the boiler enters the normal operation stage.
②. When the water level rises to a high water level, the output high water level alarm signal indicator lights up, accompanied by an electric bell, and it realizes the protection of the boiler and cuts off the power supply of the controller.
When the water level rises to + 30mm, the pump stops running, and when the water level drops to -30mmmm, the pump automatically restarts.
When the water level drops to ± 50mm, the output extremely high and extremely low water level alarm signal indicator lights up, accompanied by an electric bell, and implement a protective shutdown to cut off the power supply of the controller.
③ When the pressure rises to 0.72MPa, an over-pressure signal will sound, an electric bell will sound, and the power of the control system will be cut off to achieve an emergency shutdown.
When the pressure exceeds the upper limit of the regulated pressure, the controller outputs a small fire signal to close the large fire gas valve, and opens the small fire gas valve to burn with a small fire.
When the pressure drops below the lower limit of the regulated pressure, the controller outputs a fire signal to open the fire gas valve to burn with the fire.
④ When the burner fails, the combustion controller automatically closes the gas valve to stop combustion.
⑤ When the exhaust temperature is higher than 250 ℃, a blue indicator light is on, accompanied by an electric bell, and a protection shutdown is performed to cut off the controller power.
7. Alarm protection:
After the controller is turned on, it continuously detects the pressure sensor, water level power supply, and its own circuit. When it finds a problem, it immediately alarms and shuts down the furnace for protection. The controller automatically displays the fault point and an alarm sounds in the machine.
8. When the exhaust temperature is higher than 250 ℃, the furnace should be stopped immediately according to the requirements, and the combustible materials attached to the inner wall of the furnace should be removed; meanwhile, the air supply volume should be reasonably adjusted.

[LSS fuel gas series boiler configuration list]

Henan Taiguo Boiler Manufacturing Co., Ltd.

Configuration list of LSS type fuel oil boiler

page 1

Total 1 pages

Serial number

Drawing number or model

product name

Origin

Number

Remark

One

Boiler host

1

YXQ6530-0-0

Boiler host

Our factory

1

lifetime warranty

two

Valve instruments and safety accessories

1

Y-150

Pressure gauge 0 ~ 2 5MPa 2 Grade 5

Zhengzhou

2

One year replacement

2

X14W-1 6T

Pressure gauge tee plug

Zhengzhou

2

One year replacement

3

GGT12 01

Pressure gauge water trap

Our factory

1

lifetime warranty

4

A48H-1 6C

Full open spring safety valve PN1 6 DN80

Zhengzhou

1

One year replacement

5

J44H-1 6C

Main steam valve PN1 6 DN80

Zhengzhou

1

One year replacement

6

J44H-1 6C

Globe valve PN1 6 DN32

Zhengzhou

2

One year replacement

7

X49X-25-350

Check valve PN1 6 DN32

Zhengzhou

1

One year replacement

8

P48H-1 6Q

Water level meter PN1 6 DN25 L = 350

Zhengzhou

1

One year replacement

9

YCW6223-2-0

Drain valve PN1 6 DN50

Zhengzhou

2

One year replacement

10

J41H-1 6C

Ball valve PN1 6 DN25

Zhengzhou 2

One year replacement

11

SZB-20

Electrode type water level controller PN1 6 DN25

Nanjing

1

One year replacement

12

YMK-50-C

pressure controller

Nanjing

3

One year replacement

13

GB6780-86

Bolt M12 × 55

Jiangsu

48

One year replacement

14

GB6170-86

Nut M12

Jiangsu

48

One year replacement

three

Supporting auxiliary machine

1

YXQ6020-0-0

chimney

Our factory

1

lifetime warranty

2

YXQ6020-0-0

Chimney Elbow

Our factory

1

lifetime warranty

3

YXQ6020-0-0

Sub-cylinder

Our factory

1

lifetime warranty

4

Black & Decker BT40DSG

Burner

Black & Decker Italy

1

One year replacement

5

XD-1

Automatic computer controller

Nanjing

1

One year replacement

6

1 (1/2) GC5 × 7

Automatic water treatment

Zhengzhou

1

One year replacement

Remark

1. The quoted price of the product shall include all the above boiler auxiliary machine accessories.

2. The above boiler configuration can be changed according to customer's special requirements, which must be carried out under the guidance of our company's engineers.

3. Our company's boiler auxiliary machine accessories are constantly pursuing the highest configuration. If there is any change without notice, the contract delivery list shall prevail.